Research Tool

AOD-9604 Reconstitution Calculator

A modified fragment of human growth hormone studied in lipolysis research. This page works out concentration, volume per measured amount, syringe units and preparations per vial for a reconstituted AOD-9604 preparation, plus the mass-to-molar conversions for its stated molecular weight. Everything runs in your browser; nothing is transmitted or stored.

Also referenced as: AOD9604, Tyr-hGH fragment 176-191

Modified GH-fragment peptideMW ~1815 g/molt½ ~20-40 minutes (reported)
For research and educational purposes only. This is a unit-conversion tool for laboratory reference. It is not medical advice, not a dosing recommendation, and not an instruction for human use.

Inputs

Results

Concentration
2.5 mg/mL (2,500 mcg/mL)
Per syringe unit
25 mcg per unit
Volume per preparation
0.1 mL
Syringe units to draw
10 units
Preparations per vial
20 preparations

Worked example: a 5 mg vial reconstituted with 2 mL of bacteriostatic water. Change any input to recalculate.

A unit-conversion reference for laboratory work. Not a dosing recommendation and not an instruction for human use.

The pre-filled example, step by step

The inputs above are the neutral reference preparation this site uses everywhere the calculator appears: a 5 mg vial, 2 mL of bacteriostatic water, and a 250 mcg target amount. They are not a property of AOD-9604 and not an amount anyone should draw — they exist so the arithmetic is visible before you change anything.

  1. Concentration. 5 mg ÷ 2 mL = 2.5 mg/mL (2,500 mcg/mL), which for AOD-9604 is approximately 1.377 mM at its stated molecular weight.
  2. Per syringe unit. A U-100 syringe divides 1 mL into 100 units, so one unit holds 2,500 mcg ÷ 100 = 25 mcg.
  3. Volume for the 250 mcg target. 250 mcg ÷ 2,500 mcg/mL = 0.1 mL, or 10 units on that syringe.
  4. Preparations per vial. 5,000 mcg ÷ 250 mcg = 20 preparations.

Arithmetic on a laboratory preparation, shown as a unit-conversion reference. Not medical advice, not a dosing recommendation, not an instruction for human use. The full derivation, and why the diluent volume is a choice rather than a constant, is on the main reconstitution calculator.

Mass and molar equivalents for AOD-9604

Derived from the molecular weight recorded on the AOD-9604 entry: ~1815 g/mol — the entry states this as an approximate figure, so the equivalents below are approximate too. Concentration in molar units is what an in-vitro protocol is usually specified in.

Mass to molar conversions for AOD-9604 at its stated molecular weight.
QuantityMolar equivalent
1 mg of AOD-9604551 nmol (0.551 µmol)
1 mcg of AOD-96040.551 nmol
A 1 mg/mL solution0.551 mM (551 µM)

Molar amount = mass ÷ molecular weight. Figures are shown to four significant digits and are a unit conversion, not a measurement.

Reconstitution recorded for AOD-9604

Lyophilized; typically reconstituted with bacteriostatic or sterile water for lab handling

Quoted from the AOD-9604 entry. Amounts reported in the research literature for this compound are documented on that entry, under the disclaimer they belong with — they are not reproduced next to a calculator. Read the full AOD-9604 entry.

Handling questions for AOD-9604

How does AOD-9604 differ from unmodified HGH Fragment 176-191?

AOD-9604 is a stabilized analog of HGH Fragment 176-191: it adds a tyrosine residue at the N-terminus of the native fragment. This modification was engineered in preclinical work to improve metabolic stability and lipolytic activity relative to the raw fragment. Both are studied for fat metabolism, but AOD-9604 is the more characterized, stabilized version.

How should AOD-9604 be stored and reconstituted for research?

AOD-9604 is supplied as a lyophilized powder and is typically reconstituted with bacteriostatic or sterile water for laboratory handling. Lyophilized peptide is generally stored refrigerated (2-8 C) or frozen for longer terms; reconstituted solution is kept refrigerated and used within a limited window. A COA with HPLC purity (commonly >=98%) and mass-spec identity confirmation is standard.

Answers are published on the AOD-9604 entry. Educational summaries of research-literature context, not medical advice.

Continue exploring